Comparison table of the RADEX family devices
| Technical specifications |
|
RD1503 |
RD1503+ |
RD1706 |
| Range of ambient dose rate equivalent |
µSv/h |
from 0.05 to 9.99 |
from 0.05 to 9.99 |
from 0.05 to 999 |
| Range of exposition dose rate |
µRem/h |
from 5 to 999 |
from 5 to 999 |
- |
| Range of registered gamma radiation energy |
MeV |
from 0,1 to 1,25 |
from 0,1 to 1,25 |
from 0,1 to 1,25 |
| Range of registered X-ray radiation energy |
MeV |
- |
- |
from 0,03 to 3,0 |
| Range of registered beta radiation energy |
MeV |
- |
- |
from 0,25 to 3,5 |
Reproducibility of indications
(at confidential probability 0.95) where P is a doze rate in µSv/h
|
% |
15+6/Р |
15+6/Р |
7+6/Р |
| Threshold levels |
µSv/h |
0.30, 0.60, 1.20 |
0.10, 0.20, 0.30, 0.40, 0.50, 0.60, 0.70, 0.80, 0.90 |
from 0.1 to 99,0 |
| |
µRem/h |
30, 60,120 |
10, 20, 30, 40, 50, 60, 70, 80, 90 |
- |
| Time of calculation |
sec. |
40 ± 0.5 * |
40 ± 0.5 * |
from 26 to 1 ** |
| Time of indication |
- |
continuously |
continuously |
continuously |
| Batteries of "AAA" type |
pieces. |
one or two |
one or two |
one or two |
| Time of continuous work of a device, not less |
hour. |
550 ** |
550 *** |
500 *** |
Overall dimensions
height x breadth x depth not more than
|
mm. |
105х60х26 |
105х60х26 |
105х60х26 |
Weight (without batteries), not more than |
kg. |
0,09 |
0,09 |
0,09 |
* The increase in cycles of calculation conducts to increase of reliability of indications.
** Period of observation shortens with the increase of a dose rate more than 3,0 µSv/h.
*** Two batteries with a capacity 1350MAh, at a level of a natural background no more than 0,3 µSv/h and with factory settings.
|
| Special features of the product |
RD1503 |
RD1503+ |
RD1706 |
| Physical units of measurement |
µSv/h,
µRem/h
|
µSv/h,
µRem/h
|
µSv/h |
Quantity of SBM20-1 type Gejgera – Muller counters |
1 |
1 |
2 |
| Quantity of sound-alarm thresholds |
3 |
9 |
more than 100 |
| Reading’s qualification as the duration of observation increases |
+ |
+ |
+ |
| Disabling sound alarm |
+ |
+ |
+ |
| Vibra-call alert |
- |
+ |
+ |
| Display illumination |
+ |
+ |
+ |
Background dose capacity calculation («Background» mode) |
- |
+ |
+ |
| Adding to the memory the information on the wholesale buyer’s shop and it’s Internet address |
+ |
+ |
+ |
| Adjusting correction factor |
- |
- |
+ |
| Ability to operate with one power element of «ААА» type |
+ |
+ |
+ |
| Animation of a pressed button |
- |
+ |
- |
| Model features |
Minimal necessary set of functions |
Applied additional service functions
Convenience at premises’ inspection
Vibra signal
|
Maximal set of service functions
The range of indications is expanded 100 times
Reproducibility is twice improved Precision of indications increased twice
Time of supervision is reduced
Time of observation is reduced till 1 second when the dose rate indication are high
Convenience at premises’ inspection
Vibra signal
Adjusting correction factor
|
| Area of application |
Radiating control in day-to-day life |
For premises’ inspection
At building
Radiating control in day-to-day life
|
Personnel operating with radioactive substances
For premises’ inspection
At building
Radiating control in day-to-day life
|
|
|
|
 |
|